Author: Microengine Views: 16108Created: 27-03-2017 11:53 AM
0 Rating/ Voters
This article consists of the troubleshooting steps for general hardware problem of XP-SR200K/ XP-SR1000/ XP-SR40 reader.
Applies To:
XP-SR200K
XP-SR1000
XP-SR40
Problem
Problem with Reader, EM Lock and Door Sensor after connected to the relay board (MAS-RB)/ power lock relay unit (MAS-RB2).
Symptoms
Unable to detect card/ have no response when user flash card.
EM Lock: EM Lock cannot release/ Door is always release even security is On.
Door Sensor: No response when user pressed it.
Cause (optional)
Probably because of the following causes:
Incorrect wiring connection
No power supply to the reader
Relay board is not functional
Reader faulty
EM Lock faulty
Door Sensor faulty
Resolution Summary
Please troubleshoot the problem by testing it one by one. First, you need to identify which is the root cause of the problem. Follow the following steps.
ยป You may need other functional hardware to perform the troubleshooting steps.
Please check the wiring connection is correct upon the installation.
Check the connection to PC is using Network/ RS485 is correct.
Ensure the TTL reader is correctly connected.
Check the reader is power ON and connected to a power supply with 12Vdc, 3A.
Ensure the reader is connected to a functional relay board (MAS-RB)/ power lock relay unit (MAS-RB2).
Resolution
To solve the issues related, follow the following solution:
Connect current relay board (MAS-RB)/ power lock relay (MAS-RB2) to other functional reader.
If problem is solved, current reader have problem.
If problem persists, current relay board is faulty.
If problem persists, connect other functional relay board/ power lock relay to current reader.
If problem is solved, current relay board is faulty.
If problem persists, current reader have problem.
Connect current EM lock to other functional relay board.
If problem is solved, current relay board is faulty.
If problem persists, current EM lock have problem.
If problem persists, connect other functional EM lock to current relay board.
If problem is solved, current EM lock have problem.
If problem persists, current relay board is faulty.
Connect current door sensor to other functional relay board.
If problem is solved, current relay board is faulty.
If problem persists, current door sensor have problem.
If problem persists, connect other functional door sensor to current relay board.
If problem is solved, current door sensor have problem.
If problem persists, current relay board is faulty.
After completed the troubleshoot, if hardware was suspected faulty/ not functional, kindly return the product to the Service Center for repairing.
Custom Fields
Summary: This article consists of the troubleshooting steps for general hardware problem of XP-SR200K/ XP-SR1000/ XP-SR40 reader.
Search Tags: hardware failure, relay board, mas-rb, mas-rb2, power lock relay, reader, em lock, door sensor, faulty, not functional, door always release, flash card, no response