Knowledge Base

Knowledge Base
Advanced Search Search the Knowledgebase
Wiring connection diagram for XP-GT/ XP-GTR
Author: Microengine Views: 33411 Created: 08-06-2015 05:30 PM 0 Rating/ Voters

This article contains the wiring connection diagram for XP-GT/ XP-GTR.

Applies To:

  • XP-GT1200L, XP-GT3200L, XP-GT1200LABX, XP-GT3200LABX, XP-GT3200LE, XP-GT3200LCPX, XP-GT500LE, XP-GTR1200L, XP-GTR3200L
 Resolution Summary
 

Basic connection for the controller to communicate with the software:

  1. Connect the power terminal to the power supply.
  2. Configure the uplink connection (MCI/ LAN).
  3. Follow the wiring connection diagram to connect the other terminal correctly.
* This controller able to support up to 1 door only.

 Resolution
 

Please follow the following wiring connection diagram.

For high resolution image, please download the attached wiring diagram at the end of this article.

General wiring connection for XP-GT using MAS-RBT.




FieldConnection to MAS-RBT
Power SupplyConnect Power Supply (12VDC 3A) to terminal +12V and 0v
EM LockConnect to the terminal L/RET and L/NC
Door SensorConnect to the terminal D/S and 0V
Push ButtonConnect to the terminal P/B and 0V
DownlinkXP-GT to MAS-RBT
  • Step 1: Connect terminal DC+ to the terminal C+
  • Step 2: Connect terminal DC- to the terminal C-


General wiring connection for XP-GTR using MAS-RBU.


FieldConnection to MAS-RBU
Power Supply

Connect Power Supply (12VDC 3A) to terminal +12V and 0v

EM LockConnect to the terminal L/RET and L/NC
  • Then connect from +12V to L/CM+ and 0V to L/RET 
Door SensorConnect to the terminal D/S and 0V
Push ButtonConnect to the terminal P/B and 0V
DownlinkXP-GT to MAS-RBU
  • Step 1: Connect terminal DC+ to the terminal RB+
  • Step 2: Connect terminal DC- to the terminal RB-

FieldDescription
Reader

Connect XP-GT to external exit reader.


FieldConnection to Controller (XP-GT/ XP-GTR)
Uplink

Using Direct Serial Port:

RS232

  • Step 1: Connect uplink cable to port Uplink RS232 (Follow the label)
  • Step 2: Then connect the RS232 cable to the direct serial port at Server PC

RS485 (MCI)

  • Step 1: Connect uplink cable from the MCI to port Uplink RS485 (Follow the label)
  • Step 2: Then connect the MCI cable to the serial port at Server PC

Using LAN Port:

  • Plug in the Network/ RJ45 cable to the LAN port at the back of the controller


Please power up the controller after complete the connection.

See article below for software configuration. If this is a standalone configuration, you need not to configure the software.
Attachments
general-wiring-for-xp-gt-using-mas-rbt.pdf 0.1 Mb Download File
general-wiring-for-xp-gtr-using-mas-rbu.pdf 83.9 Kb Download File
Custom Fields
  • Summary: This article contains the wiring connection diagram for XP-GT/ XP-GTR.
  • Search Tags: wiring diagram xp-gt/ xp-gtr, drawing, xp-gt wiring, xp-gtr wiring