How to configure Auto Lock Release TZ at XP-M1000x? (New Template)
Author: Microengine Views: 63322 Created: 04-03-2016 03:19 PM 0 Rating/ Voters
This article contains steps to configure Auto Lock Release TZ using XP-M1000x. 

Applies To

  • XP-M1000x, XP-M1000x, XP-M1000ABX, XP-M1300X, XP-M1300ABX, XP-M1000XE, XP-M1000CPX 
  • XP-SR1000
Auto Lock Release Time Zone

Time Zone setting for Automatic Lock Release. This will determine at which day of the week and what time of the day will the lock be automatically release. The default value is 00.


To use the Auto Lock Release TZ

  1. Enter Programming Mode and activate the Auto Lock Release Time Zone.
    (If you don't know how to enter Programming Mode, learn how to enter to XP-M1000x Programming Mode small)

  2. Press '1' for Sys menu.
  3. Press '2' for Door Para. The screen below will be displayed:
    small

  4. Press '#' to proceed to the next item.
  5. Continue doing this until the 'ALRTz' menu displayed.
    small

  6. Set the Time Zone Code for the door will be automatically open/ release.  
    (Time Zone Code must be in a range of 00-50)

  7. Edit the values for the item displayed by keying in a new value or pressing '0' to toggle between settings. 
  8. Press '#' to proceed to the next item.
  9. Continue doing this until the Save Changes page is displayed. 
  10. Press '#' to save changes and exit from the Door Parameter setting.

    small The changes will not be saved if the configuration is interrupted midway.

  11. Finished.