How to configure Output?
Author: Microengine Views: 16141 Created: 05-11-2015 03:08 PM 0 Rating/ Voters

This article contains the steps to configure the Output.

Applies To:

  • XP-SNET 3.48 and above , XP-CPROA    
  • Software xPortalNet
 Resolution Summary
 

To configure the Output:

  1. Connect the Output at the correct relays number from the controller board.
  2. Then configure the Alarm Controller and Output Point.
  3. After completed the configuration, download the Door Settings to the controller.
 Resolution
 

Perform steps below to setup the Output.


  1. Connect the output at the correct relays number. There are 8 relays reserved for the Output on the board.


  2. If settings configured is for (Door Access + Alarm Mode), please refer table below for output configurations.
    FieldDescription

    Output Relay 1 - 5
    • Output for Door, which can connect to EM Lock.
    • Only can be triggered by IN1 - IN10 (Door Sensor and Push Button)

    Output Relay 6 - 8
    • Extra output relay.
    • Only can be triggered by IN11 - IN16 (Extra Input)

  3. If settings configured is for (Alarm Mode), please refer table below for output configurations.
    FieldDescription

    Output Relay 1 - 8
    • Only can be triggered by Sensor Input IN1 - IN16
Please ensure the controller is already configured and the status is "Up" before proceed.


Alarm Controller Setup

  1. Login to xPortalNet Server.
  2. Open Alarm Controller Setup. Go to Server Admin › System Device Setup › Alarm Controller.
  3. Add one alarm controller.

    Please select the correct Model No according to the installed alarm controller. If not connected to any alarm controller, set the Model No to Built-In IO.
  4. Click OK to confirm and save settings.


Output Point Setup

  1. Open Output Point. Go to Server Admin › System Device Setup › Output Point.
  2. Add output point according to the connected output at the controller board.

    FieldDescription
    Code and DescriptionFill in the Code and Description
    Alarm ControllerSelect Alarm Controller
    Point NoSet the Output Point - Which relay (RLY) the output is connected to.
    • Example: If Output is connected to RLY2, set the Point No to 1.
    • The Relay Point No start from 0 until 7.
  3. Please leave the Event Trigger On and Off blank. 
  4. Click OK to confirm and save settings.
    Input/ output triggering for XP-SNET/ XP-CPROA, see small How to configure Instruction Control for Input to trigger Output?

  1. Open Send Door Settings. Go to Device Comm › Send Door Setting.
  2. Download the Alarm Controller and Outputs settings to the controller.


  3. Finished.
    To configure Input, see small How to configure Input?
Attachments
snet-manual-v3.1.pdf 2.9 Mb Download File
Custom Fields
  • Summary: This article contains the steps to configure the Output.
  • Search Tags: output, output setup, how to setup output, output configuration, output point