Knowledge Base

Knowledge Base
Advanced Search Search the Knowledgebase
Unable to enter the XP-M1000x Programming Menu
Author: Microengine Views: 17655 Created: 25-06-2015 11:29 AM 0 Rating/ Voters

This article contains step to fix the problem where user unable to enter the XP-M1000x Programming Menu.

Applies To:

  • XP-M1000x, XP-M1000ABX, XP-M1300X, XP-M1300ABX, XP-M1000XE, XP-M1000CPX

 Problem
 

 Unable to enter to the Programming Menu.    

 Symptoms
 

 Unable to enter the Programming Menu after enter the default Master PIN  
› The LCD display shows *Invalid Pin!* after enter the Master PIN to enter the Programming Menu.

 Cause (optional)
 

› Incorrect Master PIN is entered.
› 
The Mode jumper at the back of the controller is in closed/ shorted condition.      

 Resolution Summary
 
  1. If cannot enter programming menu using default Master PIN, means the PIN number has been changed.
    › Please enter the new Master PIN.
     

  2. If forgot the Master PIN, perform ColdStart to restore the default Master PIN.

  3. Make sure the jumper setting is set to controller mode
    › When it act as a controller, the controller Mode jumper must be set in open condition.  

 Resolution
 
  1. Perform ColdStart to restore the default Master PIN. See small  How to reset the M1000x controller to factory default setting? (Coldstart)
    Master PIN is a six-digit PIN that is used to access the controller's Programming Menu.

  2. Please set the Mode jumper to open condition, then the XP-M1000x unit only allow to enter to the Programming Menu after the ColdStart
  3. Refer Figure 1 below:

    Figure 1
Custom Fields
  • Summary: This article contains step to fix the problem where user unable to enter the XP-M1000x Programming Menu.
  • Search Tags: programming menu, xp-m1000x, masterpin, mode jumper, unable, to, enter
Comments 2
  • [Ho alarm System]: XP-M1000X 14-02-2016 01:45 PM #

    How to enter to XP-M1000X Programming Mode

  • [Microengine ]: Re: XP-M1000X 15-02-2016 09:20 AM#

    Hi,

    Kindly refer to this article for your reference:

    http://www.microengine.net/kb/article/AA-00503