After enter the 4 digit number of Auto PIN at XP-SR200K, the EM lock does not release
Author: Microengine Views: 14972 Created: 26-02-2015 04:13 PM 0 Rating/ Voters

This article contains steps to fix the problem of XP-SR200K where the door is not release even after enter Auto PIN number.

Applies To:

  • XP-SR200KN
  • XP-SR200K  
 Problem
 

› Entered AutoPIN number to access door, but the door is not released.         

         
 Symptoms
 
 The EM Lock does not release after AutoPIN  is entered.
 The EM Lock does not release after press push button.

         
 Cause (optional)
 
 AutoPIN mode is disable.
 AutoPIN number is yet to be programmed.
 Relay board (MAS-RB) is faulty. 
 The wiring connection of relay board is incorrect.
 The reader is in Programming Mode.
 EM Lock faulty.
 Door sensor faulty.
 Reader faulty.

         
 Resolution Summary
 

Resolution 1:
 Make sure the AutoPIN number has been programmed to the reader.

Resolution 2:
 Make sure the wiring connection is correct.

Resolution 3:
 Make sure the reader is not in the Programming Mode.

Resolution 4:
 Enable the AutoPIN mode.

Resolution 5:
 Set the Lock Release Time to default value.
 Direct short wire jumper from terminal PB to 0V. 

         
 Resolution
 
Please complete the following steps below in order to resolve your issue. 

Resolution 1:
  1. Make sure the AutoPIN has been programmed to the reader. 
  2. See AA-00262 to learn how to add AutoPIN number using XP-SR200K reader.



Resolution 2:
  1. Make sure the wiring connection is correct. 
  2. See AA-00244 to learn how to check the wiring connection.



Resolution 3:
  1. Make sure the reader is not in the Programming Mode.
  2. Please ensure the Blue LED is turn off.



Resolution 4:
  1. When reader detecting a valid AutoPIN which is valid access, 
    1. Blue LED will be turn on and the EM Lock should be released.

  2. If the AutoPIN number is incorrect or invalid number, 
    1. The Red LED will be blinking and 3 beeps will be produced from the reader.

  3. If the reader does not have any respond with beep sound after enter the 4 digit AutoPIN number, please perform steps below:
    1. Enter to Programming Mode.
    2. Press "61" and press "1" to enable the AutoPIN mode.
    3. Press "#" to confirm and exit from Programming Mode.



Resolution 5:
  1. If problem persist, press the Exit Button to check whether the EM Lock can be released.
  2. If problem persist, adjust the Lock Release Time to 10 sec.
    1. Enter to the Programming Mode to set Lock Release Time to 10 sec (default).
    2. Press "72" and enter "10".
    3. Press "#" to confirm and exit from operation.

  3. If problem persist, direct short wire jumper from terminal PB to 0V. 
    1. If problem persist, Push Button faulty.
Custom Fields
  • Summary: This article contains steps to fix the problem of XP-SR200K where the door is not release even after enter Auto PIN number.
  • Search Tags: door not release, door not open, valid autoPIN, xp-sr200k
Comments
  • There are no comments for this article.