Knowledge Base

Knowledge Base
Advanced Search Search the Knowledgebase
How to access the XP-SK32 Programming Mode?
Author: Microengine Views: 16980 Created: 26-02-2015 02:07 PM 0 Rating/ Voters

This article contains steps to access the XP-SK32 Programming Mode.

Applies To:

  • XP-SK32     
 Resolution Summary
 

Resolution 1:
› Make sure the wiring connection is correct.

Resolution 2:
› Enter to Programming Menu. 
 Enter the 2 digit code which represent the programming mode/ function that need to be configured.
 Enter the specific value of each programming mode/ function setting.

         
 Resolution
 

Please complete the following steps below in order to resolve your issue. 

Resolution 1:

  1. Make sure the wiring connection is correct. 
  2. See AA-00243 to learn how to check the wiring connection.



Resolution 2:

  1. Enter to Programming Menu
  2. While in Programming Menu, Green LED will be blinking. 
  3. Follow "Steps" described below to configure the setting of each Programming Mode/ function.
    Programming ModeDescriptionSteps
    01...32
    ›PIN Number
    To edit the content of the 32 locations of 4 digit AutoPIN numbers.1. Enter one of the 2-digit number (01-32).
    2. Key in the 4 digits AutoPIN number.
    3. Press # to confirm.

    51
    MasterPIN
    To change MasterPIN
    MasterPIN used to enter Programming Mode
    1. Press 51. 
    2. Key in a 6 digits new MasterPIN number.
    3. Press # to confirm.

    52
    SuperPIN
    To change SuperPIN
    SuperPIN can toggle AutoPIN mode to on/ off during idle state
    1. Press 52. 
    2. Key in a 6 digits new SuperPIN number.
    3. Press # to confirm. 

    61
    AutoPIN Mode
    To disable or enable the AutoPIN Mode. 
    Default = Disable
    1. Press 61.
    2. Press 1 to enable or 0 to disable AutoPIN Mode.
    3. Press # to confirm. 

    62
    Security Mode
    To turn on/ off security mode. 
    Default = ON
    1. Press 62.
    2. Press 1 for ON or 0 for OFF.
    3. Press # to confirm.

    71
    Door Open Time
    To set the Door Open Time. 
    Default = 10 sec
    1. Press 71.
    2. Enter the required duration (0 – 99 sec.).
    3. Press # to confirm.
     
    72
    Lock Release Time
    To set the Lock Release Time. 
    Default = 5sec
    1. Press 72.
    2. Enter the required duration (0 – 99 sec.).
    3. Press # to confirm.
     

Custom Fields
  • Summary: This article contains steps to access the XP-SK32 Programming Mode.
  • Search Tags: xp-sk32, programming mode
Comments
  • There are no comments for this article.
Submit Feedback on this Article