Integrated Security System
The Multi-Function Security Management
System is specially design with proven and reliable advanced
technology whereby the security system like Access Control,
Alarm Monitoring, Car Park Management, Time attendance &
Payroll System, CCTV, Lift Access Control can be linked to
HR System, and this system can direct connect to controller
through Direct Modem & LAN Connectivity.
This system is operates by very powerful
software and provides great flexibility. This system
contains multiple connectivity, multiple functions, large
controller database, powerful controller settings, multiple
reader configuration, multiple door controller, configurable
security mode, alarm monitoring, lift control, event
recording, software design with latest technology, multiple
workstation, web server support, configurable remoting port,
better system user control, finger print login checking,
mobile device support, floor plan, database system, software
user level control, visitor management, an who’s still in
reporting.
This system is suitable for larger size
installation, especially for requirement that need lots of
customization.
xPortalNet Configuration Diagram
- Controller with Modem and LAN enable
Multi-Workstation Software Management System
(suitable for large organization that
intends to integrate the security system with their existing
system like HR System)
xPortalNet Features
- Multiple Connectivity
- Great Flexibility
- You can connect the controller to the server via
RS232 serial link or RS485 multidrop bus, connection
can also be achieved through a private or public
telephone network and LAN/WAN.
You can configure the controller to report alarm
events to a programmed handphone number using SMS.
- Multiple Functions -
More Powerful
- You can configure the controller to work
according to the needs of the installation.
The controller can be configured as door access, car
park access, and lift access or alarm processor.
- Large Controller
Database - Ensure Data
Integrity
- 10,000 card holder and 50,000 transactions with
data retention battery in case of power failure.
Sufficiency keeping the data even when the Server is
not online.
- Powerful Controller
Settings - Meets Stringent
Requirements
- 255 TimeSets with 3 intervals, 255 TimeZones, 30
Holidays Dates, 255 Door Access Schedules, 255 Floor
Zones, 255 Floor Access Settings.
- Multiple Reader
Configurations - Suits
Your Installation
- Reader with Keypad or Reader with Keypad and LCD
or Reader Unit only.
Proximity or Mifare® Reader Type.
- Multiple Door
Controller - Advanced
Technology
- 1/5/10/20 Door Controller. Improve connectivity
efficiency, supports multi-door anti-passback and
supports multi-door interlocking
- Configurable Security
Mode - Appropriate
Operating Mode for Appropriate Place
- Card only, Card + PIN, PIN only, Double Valid
Verification Mode (DVVM TM ), Card Holder Controlled
Security On/Off, Supervisor Mode, Door Function
Inhibit Control, Exit Button Enable Mode,
Anti-passback with or without Time Zone Control.
- Alarm Monitoring -
Function is Built-In
- 512 inputs/256 inputs/255 LED Mimic Outputs with
Event Programming.
- Event Recording -
Recording Additional Information
- You can program up to 30 event codes such as
lunch out or meeting so that the system can record
further information using the identity of the user.
You can simply flash your card at the reader
terminal and key in the event code.
- Software Design with
Latest Technology - Future
is Ensured
- Based on Microsoft Windows .Net Framework.
Employing Multi-Tiered Design and .Net Remoting
Services and Web Services. Works with Microsoft SQL
Server for greater database integrity and
flexibility. Support Windows Form Based Client using
Asp .NET.
- Web Server Support -
Accessing Using Browser
- IIS 6 with ASP.NET allows u to access the system
using web browser from any part of the world to
access the system.
- Configurable Remoting
Part - Ease of Configuring
Firewall
- The network communication Port No can be
configured manually on –site depending on the
network configuration. This will help to configure
Firewalls easily.
- Better System User
Control - Smarter
- You can configure the system to enable checking
of software user Login for account validity
automatic password expiry, wrong password lockout
account, temporary disabling.
- FingerPrint Login
Checking - The Right
Person Use the System
- You can activate the System Login checking
FingerPrint verification on top of the existing
UserID and Password.
- Mobile Device Support
- Check With Your
Handphone
- Yes. You can use your handphone to access the
system. This features is enabled using Microsoft.Net
compact framework. (Your handphone must comply to
the requirements)
- Floor Plan -
Graphical Way of Doing Things
- Integrated Floor Plan Display. 2 ways
activation. You can control by double-clicking at
the device icon. The device icon image will be
changed real-time to reflect the status of the
device.
- Database System -
Ensure Your Data is Always There
- Using Microsoft SQL Server 2000.
- Software User Level
Control - Access To The
Command is Controlled
- Each software can be assigned a software menu
command control to limit the usability of the
software user. The system is initialized with a few
default setting such as Administrator, SuperUser,
Manager, SecurityOfficer.
- Visitor Management -
Know Your Visitor
- Visitor management module helps you to keep
track of the visitor coming in and out of the
building. Visitor details can be registered with
ease by using a client workstation which can
retrieve information directly from the xPortalNet
Server. This will provide a computerized way of
recording visitor transactions which is integrated
into the access control software system.
- Who's Still IN
Reporting - In Case of
Emergency
- The xPortalNet software continuously keeps track
of the card holder movement in the premises. In case
of emergency, you might want to generate a report of
person still inside the premises or a certain area.
Our system allows you to print out this report
quickly and it would be an important piece of
information during such circumstances. Report can be
generated for Main Area or any area compound by
doors monitored xPortalNet.
| XP-CNET Controller Feature |
| No |
Product Code |
Descriptions |
| 01 |
Multiple Function Mode |
- Door Access
- Lift Access
- Car Park Access
- Alarm Monitoring
- Door Access + Alarm Monitoring
- Time Attendance
- Guard Tour
(Even recording always comes with door access
mode)
|
| 02 |
Multiple Door/Device Architecture |
1/5/10/20 with onboard CPU |
| 03 |
Multiple Connectivity |
- RS232
- RS482
- Modem dial-up with call back
- Ethernet LAN
- SMS Alarm Notification
|
| 04 |
Floor Control |
112 (Support up to 7 MTA-R16
relay controller) |
| 05 |
Sub-device supported |
- Door Interface Unit – MK747, MK800,
MK1200
- Alarm Controllers – MTA-R16, MTA-S168,
MTA-L32
- Lift Relay Controller – MTA-R16
|
| 06 |
Downlink Type |
RS482 wires |
| 07 |
Device Capacity |
- 1/5/10/20
- Door Access: 1/5/10/20 Doors
- Lift Access: 1 reader + 112 floors (7
MTA-R16)
- Car Park Access: 1/2/10/20 barriers
- Alarm Monitoring: 256 supervised inputs and
128 relay outputs
- Door Access + Alarm Monitoring: 1/5/10/20
doors + 64 inputs/32 outputs
|
| 08 |
Card User Capacity |
10,000 |
| 09 |
Transaction Capacity (First
IN/First OUT basic)
For Time Attendance mode,buffer full detention is
enabled |
20,000/50,000 |
| 10 |
TimeSets |
255 |
| 11 |
TimeZones |
255 |
| 12 |
Holidays |
30 |
| 13 |
Door Access Schedules |
255 |
| 14 |
Floor Zones |
255 |
| 15 |
Floor Access |
255 |
| 16 |
Built-In Real-Time Clock |
 |
| 17 |
Built-In onboard data retention
battery |
 |
| 18 |
Support LCD 4x20 and 16 keys keypad
for programming |
 |
| 19 |
Built-In System Operating Monitoring
Circuit |
 |
| 20 |
Call Back Event |
20 events of call back can be
configured |
| 21 |
Site Code |
10 |
| 22 |
Reader Operation Mode |
- PIN only
- Card only
- Card + PIN
- FingerPrint
- FingerPrint + Card + PIN
(with TimeZone control)
|
| 23 |
Multiple Reader Support |
- Proximity
- Mifare
- BarCode
- Magnetic Swipe
- FingerPrint
- Iris
- Format: ABA Track 2 or Wiegand 26
|
| 24 |
Event Recording |
30 event codes |
| 25 |
Duress Alarm |
 |
| 26 |
Exit button with TimeZone control |
 |
| 27 |
Door Access:
- Supervisor Mode
- Door Inhibit Mode
- Card User Controlled Door Security On/Off
with TimeZone control
- InterLocking Mode
|




|
| 28 |
Car Park Access:
- Auto Anti-Passback Reset Time
- Vehicle Counting
- Present Loop Detect to Read Card
- Car Park Zone Duration Control
|




|
| 29 |
Alarm Monitoring:
- Event Program
- Alarm Arming TZ/Manual
- Output Activation TZ/Manual
- Mimic LED Panel
- Keyswitch Alarm Acknowledgement
- Guard Tour
- Alarm Control from Reader Keypad
|
99






|
| 30 |
Online Printing |
Using MK-PRN Printer Interface Unit |
| 31 |
Password Controlled |
2 levels |
| 32 |
Onboard Buzzer |
 |
| 33 |
Power |
12VDC @ 0.5A Typical |
| 34 |
Casing |
Metal with epoxy coating |
| Server |
| Item |
System |
Software Models |
| xPortalNet/1 |
xPortalNet/3SE |
xPortalNet/3S |
| 01 |
CPU (minimum) |
Pentium 1.8GHz |
Pentium 1.8GHz |
Pentium 2.4GHz |
| 02 |
RAM (minimum) |
512 MB |
1 GB |
2 GB |
| 03 |
OS |
Microsoft XP Pro,
2000 Pro, 2000 Server, 2003 Server |
Microsoft XP Pro,
2000 Pro, 2000 Server, 2003 Server |
Microsoft 2000
Server, 2003 Server |
| 04 |
Microsoft .Net Framework v1.1 |
 |
 |
 |
| 05 |
Microsoft SQL Server 2000 |
|
|
 |
| 06 |
Ethernet |
 |
 |
 |
| 07 |
Serial Port |
 |
 |
 |
| 08 |
Display (1024 x 768 x 16 bit
colours) |
 |
 |
 |
| 09 |
Mouse |
 |
 |
 |
| 10 |
Keyboard |
 |
 |
 |
| 11 |
UPS (recommended) |
 |
 |
 |
| 12 |
Harddisk (minimum free space) |
20 GB |
30 GB |
40 GB |
| 13 |
Backup Drive (recommended) |
 |
 |
 |
| PC Client |
| No |
System |
Requirements |
| 01 |
CPU (minimum) |
Pentium 1.8Ghz |
| 02 |
RAM (minimum) |
512 MB |
| 03 |
OS |
Microsoft ME, XP
Home, XP Pro, 2000 Pro, 2000 Server, 2003 Server |
| 04 |
Microsoft .Net Framework v1.1 |
 |
| 05 |
Ethernet |
 |
| 06 |
Display (1024 x 768 x 16 bit
colours) |
 |
| 07 |
Mouse |
 |
| 08 |
Keyboard |
 |
| 09 |
Harddisk (minimum free space) |
10 GB |
| Ordering Information |
| No |
Product Code |
Descriptions |
| 01 |
XP-CNET5 |
xPortalNet 5 Controller 10,000 Users, 20,000
Transactions, RS485, RS232 |
| 02 |
XP-CNET10 |
xPortalNet 10 Controller 10,000 Users, 20,000
Transactions, RS485, RS232 Ethernet LAN, Door &
Lift Access, Alarm Monitoring |
| 03 |
XP-CNET20 |
xPortalNet 20 Controller 10,000 Users, 50,000
Transactions, RS485, RS232 Ethernet LAN, Door &
Lift Access, Alarm Monitoring |
| 04 |
XP-CPRO5 |
xPortal 5 Door Controller 10,000 Users, 10,000
Transactions, RS485 |
| 05 |
XP-CPRO10 |
xPortal 10 Door Controller 10,000
Users, 10,000 Transactions, RS485 |
| 06 |
xPortalNet/1 |
xPortalNet Software c/w 1
Communicator Single Desktop Version Access Database |
| 07 |
xPortalNet/3 SE |
xPortalNet Software c/w 1
Communicator (Special Edition) 3 Client Version
Access Database |
| 08 |
xPortalNet/3 |
xPortalNet Software c/w 1
Communicator 3 Client Version Runs on Microsoft SQL
Server Database |
| 09 |
xPortalNet/5 |
xPortalNet Software c/w 1
Communicator 5 Client Version Web Browser Access
Runs on Microsoft SQL Server Database |
| 10 |
MK-800 |
Door Interface Unit |
| 11 |
XP-M1000 |
Single Door Controller c/w
LCD/Keypad/Proximity Reader |
| 12 |
XP-C1200 |
Single Door Controller |
| 13 |
MK-1200 |
Door Interface Unit Interface with
Built-In Memory |
| 14 |
XP-RDPRX |
Proximity Reader |
| 15 |
XP-RDPRX-K |
Proximity Reader with LCD /Keypad |
| 16 |
XP-RDMFR |
Mifare Serial Number Reader with
LCD/Keypad |
| 17 |
XP-RDMFR-N |
Mifare Serial Number Reader |
| 18 |
MCI-VMSCS |
xPortalVMS Visitor Management
System |
| 19 |
XP-VMSCS/L |
xPortalVMS Client License Pack
(includes 1 Client Access License and 1 unit of
XP-MYKADUSB MyKAD Reader) |
| 20 |
MV-25 |
LAN Interface Unit |
| 21 |
MV-26 |
Modem Interface Unit |
| 22 |
MV-GSM |
Modem Interface (for SMS
Notification) |