The Integrated Access Control System for Door, Lift and Car park is suitable for medium to large size installation. It is designed with proven and reliable technology.
The Comprehensive reporting function enable user to generate various type of reports with criteria selection. For example, report for Late-Comer, Early-Leaver, Absenteeism, Early-Comer, Late-Leaver and OT. Also, the User friendly software contains a Dynamic Floor Plan features.
With the Built-In Visitor Management module, the system able to keep track visitor visiting the building.
This system is operates by access management software, it supports access management, automatic data collection, time attendance function, and Client-Server Version. It is easy to program and easy to maintain.
|
|
|
|
|
|
|
|
|
 |
-
Efficient Design
-
-
Suitable for medium to large size installation
-
Distributed Multi Door Controller Architecture
-
-
One controller for each door
-
-
Onboard battery backed memory and clock
-
-
Can operate without PC being online
-
-
Use RS485 (2 wires) to network to controllers
-
-
5/10/20 doors per controller
-
Multi-Door Anti-passback
-
-
Multi-door anti-passback under one controller
-
-
Important for user tracking
-
-
Better control for zone restriction
-
User-friendly software with dynamic floor plan
-
-
Outlook based user interface
-
-
-
-
Can click on door icon for operation (easy to use)
-
Comprehensive reporting functions
-
-
Generates various type of reports with criteria selection
-
-
Software user activities events logging
-
Built-In Powerful Time Attendance Reporting
-
-
Analyze data to automatically produce standard attendance report
-
-
Can generate reports for late-comer, early-leaver, absenteeism, early-comer, late-leaver, and OT
-
-
Helps monitor the attendance of the staff
-
Built-In Visitor Management Module
-
-
Keep tracks of visitor visitng the building
-
-
Can generate reports for visitor movement
-
Reliable Technology
-
-
Design with proven and reliable technology
-
-
Built-in System Integrity Monitoring system for maximum reliability
|
|
|
AccessPortal XP-CPRO5/10/20 Door Controller Features
|
|
|
 |
|
No |
Feature |
Functions |
|
01 |
Autonomy |
Distributed data and processing |
|
02 |
Downlink port |
2 wire RS485 |
|
03 |
Battery backed real time click |
Yes |
|
04 |
Onboard rechargeable battery |
Yes |
|
05 |
Card number |
6 digits |
|
06 |
Continuous reads when door left open |
Yes |
|
07 |
Operating modes |
Card, PIN, or both |
|
08 |
Support tamper & buzzer at reader |
Yes |
|
09 |
Time Zone |
255 |
|
10 |
Time Set |
255 each with 3 intervals |
|
11 |
Holidays |
30 |
|
12 |
Onboard watchdog circuit |
Yes |
|
13 |
Anti-passback |
Yes |
|
14 |
Configurable lock release time |
Yes (0-99 secs) |
|
15 |
Configurable door open time |
Yes (0-99 secs) |
|
16 |
Auto PIN |
Yes (10 Sets, 4 digits each) |
|
17 |
Auto Lock release by time zone |
Yes |
|
18 |
Card & PIN by time zone |
Yes |
|
19 |
Door release button |
Yes |
|
20 |
Exit push button time zone control |
Yes |
|
21 |
Door sense input |
Yes |
|
22 |
Cardholders
|
|
|
23 |
Events
|
|
|
24 |
RAM memory |
At least 128KByte |
|
25 |
RAM protected by On board battery |
Yes |
|
26 |
Firmware EPROM/flash memory |
At least 128KByte |
|
27 |
Addressing via dip switch |
Yes |
|
28 |
Onboard buzzer |
Yes |
|
29 |
Communication ports |
RS485 |
|
30 |
Polarity protection for power connector |
Yes |
|
31 |
Power |
12VDC |
|
32 |
Duress Alarm |
Yes |
|
33 |
Reader Interface Card |
MK800 |
|
|
|
AccessPortal XP-CPRO Software Features
|
|
|
 |
|
No |
Feature |
Functions |
|
01 |
Operating system |
Windows 95, 98, NT or higher |
|
02 |
Capacity |
Up to 320 doors |
|
03 |
Communication |
Multi-drop RS485 |
|
04 |
No. of comm bus |
1, 2, 4, (depending on model) |
|
05 |
Communication interface unit |
MCI-XPPRO |
|
06 |
Controller |
XP-C1000, XP-CPRO series |
|
07 |
Cardholders |
5,000 |
|
08 |
Operators |
30 |
|
09 |
Operator access levels |
30 |
|
10 |
Operator password |
Yes |
|
11 |
Access levels |
255 |
|
12 |
Holidays |
30 |
|
13 |
Time Zones |
255 |
|
14 |
Time Sets |
255 |
|
15 |
Intervals per time set |
3 |
|
16 |
Anti-passback |
Yes |
|
17 |
Time attendance |
-
Single Day Daily Attendance Report
-
Monthly Summary Reporting
|
|
18 |
Floor plan |
30 |
|
19 |
Floor plan breakthrough on alarm |
Yes |
|
20 |
GUI floor plan |
Yes |
|
21 |
User photo display |
Yes |
|
22 |
User-define PIN selection |
Yes |
|
23 |
PIN |
4 digits |
|
24 |
Online events viewing |
Yes |
|
25 |
Online help |
Yes |
|
26 |
Shortcut keys |
Yes |
|
27 |
Automatic transaction logging |
Yes |
|
28 |
Event logging for all actions by operator |
Yes |
|
29 |
User define company name and logo display |
Yes |
|
30 |
Comprehensive report generation |
Yes |
|
31 |
Reporting based on staff number |
Yes |
|
32 |
Extension search for data |
Yes |
|
33 |
Housekeeping utilities |
Backup, restore, purging of events |
|
34 |
Individual or group door release from PC |
Yes |
|
35 |
DBASE IV database format |
Yes |
|
36 |
Multi-lingual support |
Yes (Optional) |
|
37 |
Remote Controlling through LAN/Modem |
Yes (Optional) |
|
38 |
Multi-workstation system |
Yes (Optional) |
|
|
|
|
|
|
|
 |
|
No |
Product Code |
Descriptions |
|
01 |
XP-CPRO5 |
5 Door Access Controller |
|
02 |
XP-CPRO10 |
10 Door Access Controller |
|
03 |
XP-CPRO20 |
20 Door Access Controller |
|
04 |
XP-CPRO2L |
Lift Access Controller (2 COP) |
|
05 |
MK800 |
Reader interface card MicroEngine XP-RDPRX & XP-RDPRX-K |
|
06 |
XP-RDPRX |
MicroEngine Proximity Reader |
|
07 |
ZP-REPRX-K |
MicroEngine Proximity Reader with LCD keypad |
|
08 |
MV-25 |
LAN Interface Unit |
|
09 |
MV-26 |
Modem Interface Unit |
|
10 |
MPS-30 |
Power Supply 13.8V/3A |
|
11 |
MPS-40 |
Power Supply 13.8V/3A with Low Power Cut Off |
|
12 |
MPC-100 |
Clamshell Proximity Card (1.9mm thick) |
|
13 |
MCI-XPPRO/1 |
XPPRO Software for controlling 1 unit of XP-C1000 or XP-CPRO series controller C/W signal converter |
|
14 |
MCI-XPPRO/16 |
XPPRO Software for controlling 16 unit of XP-C1000 or XP-CPRO series controller C/W signal converter |
|
15 |
MCI-XPPRO/REMOTE/16 |
XPPRO Software for controlling 16 unit of XP-C1000 or XP-CPRO series controller with Modem/LAN connectivity C/W signal converter |
|
16 |
MCI-XPPRO/32 |
XPPRO Software for controlling 32 unit of XP-C1000 or XP-CPRO series controller C/W signal converter (Requires 2 comm ports) |
|
17 |
MCI-XPPRO/64 |
XPPRO Software for controlling 64 unit of XP-C1000 or XP-CPRO series controller C/W signal converter (Requires 4 comm ports) |
|
|
|
|
|
 |
|
No |
Feature |
Functions |
|
01 |
Processor |
Intel Pentium III 733 MHz or better |
|
02 |
RAM |
128 MB or larger |
|
03 |
Harddisk |
At least 50MB for program and 500MB for storage |
|
04 |
Display |
800x600 256 colors or better |
|
05 |
Peripherals |
1 comm port |
|
06 |
Mouse |
Yes |
|
07 |
Keyboard |
Yes |
|
08 |
UPS |
Recommended to install |
|
09 |
OS |
Microsoft Windows 98, ME, NT4, 2000 or compatible |
|
|
|
|
|
 |
|
|
|
|