How to connect XP-SR40 to an EM Lock?
Author: Microengine Views: 18983 Created: 25-02-2015 09:35 AM 0 Rating/ Voters

This article contains the wiring connection diagram for XP-SR40. The connection shows how to connect the XP-SR40 to an EM Lock.

Applies To:

  • XP-SR40
 Resolution Summary
 

Configure the wiring connection of the controller according to the wiring diagram provided. Ensure the controller, reader and relay board are supplied with power with 12Vdc, 3A. 

Turn ON the power after complete the wiring connection. Please verify that the MAS-RB2 relay board is functional. (Ensure the relay board is producing power) 

  1. Check the wiring connection is correct upon the installation.   
  2. Check the reader can be power ON after connected to a power supply with 12Vdc, 3A.
  3. Ensure the EM Lock will be in lock condition during Idle Mode after install 3 Master Cards. 

 Resolution
 

Please complete the following steps below.

Refer to the attached wiring diagram at the end of this article for best view. 


Configure the wiring connection according to the following wiring diagram.

  1. Power ON the reader by connect it to a power supply with 12Vdc, 3A.
  2. Make sure the terminal output from MAS-RB2 to lock is producing correct voltage level.
  3. To measure the voltage level at terminal output of MAS-RB2, connect the Multimeter's Red Probe to the L/NC and Black Probe to the L/RET.
    1. When door security status is ON, the EM Lock should be in locked condition. 
      » The voltage measured at terminal L/NC and L/RET showed is about 12V (±10 %)

    2. When door security status is OFF, the EM Lock should be in unlocked condition (Door released).
      » The voltage measured at terminal
       L/NC and L/RET approximately +12Vdc (±10 %)

  4. Make sure the EM Lock is released when pressing the exit button. LED on the MAS-RB2 will turned on when EM Lock is released.
Attachments
wiring-diagram mas-rb2.pdf 0.6 Mb Download File
Custom Fields
  • Summary: This article contains the wiring connection diagram for XP-SR40. The connection shows how to connect the XP-SR40 to an EM Lock.
  • Search Tags: wiring diagram xp-sr40, em lock, connection, drawing, xp-sr40 wiring, mas-rb, mas-rb2
Comments
  • There are no comments for this article.
Submit Feedback on this Article